Home ProductsFactory Air Conditioners

Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion

Certification
China Dongguan Lixian Instrument Scientific Co.,LTD certification
China Dongguan Lixian Instrument Scientific Co.,LTD certification
I'm Online Chat Now

Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion

Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion
Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion

Large Image :  Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion

Product Details:
Place of Origin: China
Brand Name: Taikang
Certification: CE
Model Number: Model G50TH G71TH
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: negotiate
Packaging Details: wood
Delivery Time: 7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: negotiate

Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion

Description
Model: G50TH G71TH Items: Hanging Type (combined) Frequency Conversion Constant Temperature And Humidity
Number Of P: 2 3 5 6 6 8 9 10 P Temperature Setting Range And Control Accuracy: 18~25℃±1℃
Humidity Setting Range And Control Accuracy: 45~65%±5% Power: Three-phase380V/~/50Hz
Refrigerant: R410A Evaporator: Copper Tube Finned
Highlight:

R410A Refrigerant Factory Air Conditioners

,

380V 50Hz Factory Air Conditioners

,

Hanging Type Frequency Conversion Air Conditioner

Hanging Type Factory Air Conditioner Three-Phase380V/~/50Hz Frequency Conversion Constant Temperature And Humidity

 

Factory Air Conditioner s used for indoor air conditioning under various environmental conditions, and has multiple functions such as cooling, dehumidification, heating, humidification, and ventilation. Temperature control range: when the temperature is set at 18-25°C, the control accuracy is ±0.5-1°C, the relative humidity is set at 50-70%, and the control accuracy is ±5-10%.

 

Factory Air Conditioner Cooling principle:

When the refrigeration system is working, the high-temperature and high-pressure R410 gas discharged from the compressor enters the condenser and is condensed into a medium-temperature supercooled liquid. After being throttled and depressurized by the expansion valve, it becomes a low-temperature and low-pressure gas-liquid two-phase mixture and enters the evaporator. It evaporates and absorbs the heat of the air passing through the evaporator, so that the air flowing through the evaporator can be cooled. After vaporization, the steam is sucked by the compressor, so that the cycle is continuous, so as to achieve the purpose of cooling.

 

Factory Air Conditioner Dehumidification principle:

Since the surface temperature of the fins of the evaporator is lower than the dew point temperature of the air, when the air flows through the surface of the evaporator, water will precipitate on the surface of the evaporator.

Heating: start the heater, when the air flows through the heater, the air is heated and the temperature rises.

Humidification: Start the humidifier, and the water vapor generated by the humidifier is continuously sent into the room by the fan to achieve the purpose of humidification..

 

Factory Air Conditioner Application

The unit has a variety of models to choose from, and can be widely used in the air conditioning needs of electronic factories, hospitals, pharmaceutical factories, printing factories, post and telecommunications, banks, computer rooms, power supply and distribution stations, communication stations and other buildings.

 

Technical Parameters

items Hanging constant temperature and humidity
Model Indoor Unit G50TH G71TH
  outdoor unit TK-WB TK71WB
number of p P 2 3
Cooling capacity kW 5 7.1
Electric heating kW 7.5 15
indoor unit air volume m3 / h 1150 1700
External residual pressure Pa 50/0 50/0
noise dB(A) 52/54 54/56
Temperature setting range and control accuracy 18~25℃±1
Humidity setting range and control accuracy 45~65%±5%
power 220V/~/50Hz
Refrigerant R410A
Evaporator Copper tube finned
throttling mode Electronic expansion valve
wind machine Type Cross flow centrifugal fan
  Power kW 0.06 0.08
heater Type PTC electric heater
  Power kW 3 6
Humidifier Type PTC electric heater
  Power kW 1.8 2
  Humidification capacity kg/h 1.3 1.5
  Inlet pipe diameter - DN15
Maximum input power kW 5 6

 

 

 

Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion 0

 

Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion 1

Hanging Type Factory Air Conditioners Three Phase 380V 50Hz Frequency Conversion 2

Contact Details
Dongguan Lixian Instrument Scientific Co.,LTD

Contact Person: liang

Tel: 8613711888650

Fax: 86--13827265866

Send your inquiry directly to us (0 / 3000)