Product Details:
|
Items: | Cabinet Type (combined) Frequency Conversion Constant Temperature And Humidity | Power: | Three-phase380V/~/50Hz |
---|---|---|---|
Number Of P: | 2 3 5 6 6 8 9 10 P | Refrigerant: | R410A |
Model: | L125TH L150TH L150TH2 L200TH L225TH L250TH | Evaporator: | Copper Tube Finned |
Temperature Setting Range And Control Accuracy: | 18~25℃±1℃ | Humidity Setting Range And Control Accuracy: | 45~65%±5% |
Highlight: | 380V Factory Air Conditioner,Copper Tube Finned Factory Air Conditioner,R410A Frequency Conversion Air Conditioner |
PCB Board Clean Room Air Conditioner Frequency Conversion Factory Air Conditioner Three-Phase380V/~/50Hz
Factory Air Conditioner s used for indoor air conditioning under various environmental conditions, and has multiple functions such as cooling, dehumidification, heating, humidification, and ventilation. Temperature control range: when the temperature is set at 18-25°C, the control accuracy is ±0.5-1°C, the relative humidity is set at 50-70%, and the control accuracy is ±5-10%.
Factory Air Conditioner Cooling principle:
When the refrigeration system is working, the high-temperature and high-pressure R410 gas discharged from the compressor enters the condenser and is condensed into a medium-temperature supercooled liquid.
Factory Air Conditioner Dehumidification principle:
Heating: start the heater, when the air flows through the heater, the air is heated and the temperature rises.
Humidification: Start the humidifier, and the water vapor generated by the humidifier is continuously sent into the room by the fan to achieve the purpose of humidification..
Technical Parameters
items | frequency conversion constant temperature and humidity | ||||||||
Model | Indoor Unit | L125TH | L150TH | L150TH2 | L200TH | L225TH | L250TH | ||
outdoor unit | TK-125WB | TK-150WB | TK-150WB | TK200WB | TK225WB | TK250WB | |||
number of p | P | 5 | 6 | 6 | 8 | 9 | 10 | ||
Cooling capacity | kW | 12.5 | 15 | 15 | 20 | 22.5 | 25 | ||
Electric heating | kW | 23.4 | 28 | 28 | 36 | 41 | 47 | ||
indoor unit | air volume | m3 / h | 2500 | 3600 | 3500 | 5000 | 5000 | 5400 | |
External residual pressure | Pa | 50/0 | 60/0 | 80/0 | 80/0 | 80/0 | 80/0 | ||
noise | dB(A) | 58/60 | 58/60 | 58/60 | 62/64 | 62/64 | 62/64 | ||
Temperature setting range and control accuracy | 18~25℃±1℃ | ||||||||
Humidity setting range and control accuracy | 45~65%±5% | ||||||||
power | 220V/~/50Hz | Three-phase380V/~/50Hz | |||||||
Refrigerant | R410A | ||||||||
Evaporator | Copper tube finned | ||||||||
throttling mode | Electronic expansion valve | ||||||||
wind machine | Type | Cross flow centrifugal fan | |||||||
Power | kW | 0.16 | 0.18 | 0.16 | 0.22 | 0.24 | 0.26 | ||
heater | Type | PTC electric heater | |||||||
Power | kW | 8 | 11 | 11 | 14 | 16 | 18 | ||
Humidifier | Type | PTC electric heater | |||||||
Power | kW | 2.5 | 3 | 3 | 4 | 4 | 4.5 | ||
Humidification capacity | kg/h | 2.8 | 3.4 | 3.4 | 4.5 | 4.5 | 5 | ||
Inlet pipe diameter | - | DN15 | |||||||
Maximum input power | kW | 8.5 | 11 |
Factory Air Conditioner Features
Factory Air Conditioner Advantage:
1. Few limitations. Small areas can be directly blown by small cooling capacity cabinet machines, and large areas can be cooled by large cooling capacity direct blowing machines, duct machines or horizontal machines.
2. Easy to maintain, easy to install, easy to clean and not easy to break down
3. Less investment in the early stage and low cost in the later stage. Our machines are cheaper than traditional air conditioners with the same cooling capacity. In the later period, it can save electricity by 30%-50% compared with traditional air conditioners. It can save electricity by 15% compared with central air conditioners.
4. Good cooling effect and fast cooling speed. The air volume is large, and the air supply is far away.
5. The temperature can be adjusted according to the demand, and it has a dehumidification effect.
6. Different solutions can be used in different environments according to requirements. The direct blowing type of the traditional air conditioner can be used to cool down the overall temperature in a sealed condition. Post air supply using environmentally friendly air conditioners cools down at designated workplaces. The central air supply type using the central air conditioner is more beautiful. We will come up with solutions according to what customers need.
7. Does not take up space. One of our 125 series machines can manage 100-130 square meters. The indoor unit can be installed on the floor indoors, hung on the wall, or placed outdoors.
8. There is no requirement for the degree of sealing, the overall cooling of the sealed environment is direct blowing, and the post-type air supply is used for regional cooling in the unsealed environment.
9. Simple maintenance and low maintenance cost. Important components such as the compressor are in the internal machine, so there is no need to work outdoors at high altitude.
10. The compressor load is small, the failure rate is low, and the service life is longer.
shortcoming:
There are requirements on water quality and tap water is required.
Factory Air Conditioner Application
The unit has a variety of models to choose from, and can be widely used in the air conditioning needs of electronic factories, hospitals, pharmaceutical factories, printing factories, post and telecommunications, banks, computer rooms, power supply and distribution stations, communication stations and other buildings.
Contact Person: liang
Tel: 8613711888650
Fax: 86--13827265866