Product Details:
|
Evaporator: | Copper Tube Finned | Temperature Setting Range And Control Accuracy: | 18~25℃±1℃ |
---|---|---|---|
Humidity Setting Range And Control Accuracy: | 45~65%±5% | Power: | Three-phase380V/~/50Hz |
Refrigerant: | R410A | Number Of P: | 2 3 5 6 6 8 9 10 P |
Model: | G50TH G71TH | Items: | Hanging Type (combined) Frequency Conversion Constant Temperature And Humidity |
Highlight: | Copper Tube Finned Factory Air Conditioners,CE Factory Air Conditioners,R410A Hospital Air Conditioner |
Factory Air Conditioner s used for indoor air conditioning under various environmental conditions, and has multiple functions such as cooling, dehumidification, heating, humidification, and ventilation. Temperature control range: when the temperature is set at 18-25°C, the control accuracy is ±0.5-1°C, the relative humidity is set at 50-70%, and the control accuracy is ±5-10%.
Factory Air Conditioner Application
The unit has a variety of models to choose from, and can be widely used in the air conditioning needs of electronic factories, hospitals, pharmaceutical factories, printing factories, post and telecommunications, banks, computer rooms, power supply and distribution stations, communication stations and other buildings.
Technical Parameters
items | Hanging constant temperature and humidity | ||||
Model | Indoor Unit | G50TH | G71TH | ||
outdoor unit | TK-WB | TK71WB | |||
number of p | P | 2 | 3 | ||
Cooling capacity | kW | 5 | 7.1 | ||
Electric heating | kW | 7.5 | 15 | ||
indoor unit | air volume | m3 / h | 1150 | 1700 | |
External residual pressure | Pa | 50/0 | 50/0 | ||
noise | dB(A) | 52/54 | 54/56 | ||
Temperature setting range and control accuracy | 18~25℃±1℃ | ||||
Humidity setting range and control accuracy | 45~65%±5% | ||||
power | 220V/~/50Hz | ||||
Refrigerant | R410A | ||||
Power | kW | 0.06 | 0.08 | ||
heater | Type | PTC electric heater | |||
Power | kW | 3 | 6 | ||
Humidifier | Type | PTC electric heater |
Factory Air Conditioner Cooling principle:
When the refrigeration system is working, the high-temperature and high-pressure R410 gas discharged from the compressor enters the condenser and is condensed into a medium-temperature supercooled liquid. After being throttled and depressurized by the expansion valve, it becomes a low-temperature and low-pressure gas-liquid two-phase mixture and enters the evaporator. It evaporates and absorbs the heat of the air passing through the evaporator, so that the air flowing through the evaporator can be cooled. After vaporization, the steam is sucked by the compressor, so that the cycle is continuous, so as to achieve the purpose of cooling.