Product Details:
Place of Origin: China
Brand Name: lixian
Certification: CE
Model Number: HZ-2012A
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: wood
Delivery Time: 7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram

0.2Mpa-0.5Mpa Environmental Testing Machine Multifunctional Stable

Description
Corresponding Standard :: SJ/T10187-91Y73, SJ/T10186-91Y73, IEC68-2-14 Temprature Range: -77 Degree ~+205 Degree
System: 2-zone Transition By Vertical Transfer Of Specimens Material: Stainless Steel
Application: Industry,Machinery Parts,Auto Part Dimensions: Customized Sizes
Service: OEM ODM Standard: GB ASTM AISI DIN BS,DIN,BS,ASTM,ISO
Color: Customer Required Size: Customized Size
Highlight:

0.2Mpa Environmental Testing Machine

,

0.5Mpa Environmental Testing Machine

,

Multifunctional Climate Test Chamber

IEC68-2-14 High And Low Temperature Alternating Test Box Din 50017 Climate Test Chamber Temperature Shock Chambers

 

Chamber summary:
The thermal shock test chamber, also known as the high and low temperature impact test chamber, is known as the cold and thermal impact machine in Taiwan.
Specification:
Model
HZ-2012 Water-cooled
System
2-zone transition by vertical transfer of specimens
Performance *1

Test area
Hot exposure range
+ 60℃ to + 205℃
Cold exposure range
−77℃ to 0℃
Temp. fluctuation *2
± 1.0℃
Hot chamber
Pre-heat upper limit
+ 205℃
Heat-up time *3
Within 90 min from ambient temp.
to + 200℃ (Setting: + 205℃)
Cold chamber
Pre-cool lower limit
−77℃
Pull-down time *3
Within 90 min from ambient temp. to −77℃ (Setting: −77℃)

Ambient recovery

Recovery conditions
・Hot exposure: +150℃ to max. + 55℃
・Ambient temp.: + 23℃
・Specimen: Plastic molded ICs, 10 kg
 
Ambient temp. recovery time
Within 90 min
Test area
Shelf brackets on 2 levels (up to 4 baskets can be installed)
Elevating unit
Power slider (250W)

Fittings
USB memory port, Ethernet port (LAN port),
specimen power supply control terminal,
time signal output terminal (× 2),
specimen temperature input terminal (× 2),
cable port ID φ 100mm on right side
(left side available as option),
*Power cables not included.
Inside dimensions
W710×H345×D410 mm
Test area capacity
100 L
Load capacity of test area *4
30 kg
Outside dimensions *5
W1100×H1885×D1965 mm
Weight
Approx. 1100 kg
Utility requirements
Ambient temp. range
+ 5℃ to + 40℃
Piping connection size
Carbon steel pipe, ID 32 mm
Cooling water temp. range
+ 5℃ to + 38℃
Noise level *10
Max. 65 dB
Exhaust heat rate
12600 kJ/h (3000 kcal/h)
Exhaust air volume
250 m3/h
Main function:
Used in electrical and electronic components, automation components, communication components, auto parts, metals, chemical materials, plastics, etc., defense industry, aerospace, military industry, BGA, PCB base board, electronic chip IC, semiconductor ceramics and polymer materials The physical change, testing the material's repeated tensile force against high and low temperature and chemical changes or physical damage of the product in thermal expansion and contraction, can confirm the quality of the product, from precision IC to heavy mechanical components, no one Ideal test tool without it.
 
The difference between two boxes and three boxes:
The two slots are composed of a cold box and a hot box, the box does not move, and the sample is tested in the manner that the hanging bar is switched between the cold box and the hot box. The three tanks are composed of a cold box, a hot box and a test box, and are tested by means of air flow conversion of the object to be tested and the cold box and the hot box.
 
Corresponding standard :
1,GB/T2423.1-1989
2,GB/T2423.2-1989
3,GB/T2423.22-1989
4,GJB150.5-86
5,GJB360.7-87
 
Application industry:
Applicable to aviation, military, ship, electrician, electronics, instrumentation; medical equipment; civil nuclear energy; colleges and universities; research institutes; commodity inspection and arbitration, technical supervision departments; building materials ceramics; petrochemical products, complete machines and parts High and low temperature impact test.
0.2Mpa-0.5Mpa Environmental Testing Machine Multifunctional Stable 0
0.2Mpa-0.5Mpa Environmental Testing Machine Multifunctional Stable 10.2Mpa-0.5Mpa Environmental Testing Machine Multifunctional Stable 2
0.2Mpa-0.5Mpa Environmental Testing Machine Multifunctional Stable 3

Contact Details
Dongguan Lixian Instrument Scientific Co.,LTD

Contact Person: liang

Tel: 8613711888650

Fax: 86--13827265866

Send your inquiry directly to us (0 / 3000)