HDT Heat Distortion Temperature Standard Vicat Softening Point Apparatus
Equipment overview
It is mainly used for the determination of heat distortion temperature and Vicat softening point temperature of non-metallic materials such as plastic, hard rubber, nylon, electrical insulating materials, long fiber reinforced composite materials, high strength thermosetting laminates. It is easy to operate and precise in control. It is a highly intelligent test instrument widely used in colleges and universities, research institutes and product quality supervision and inspection units.
Features
Multiple security protection: Mechanical temperature upper limit protection switch, software temperature upper limit protection, to ensure safe and stable operation of the test. High-precision measurement and control system: The high-performance temperature sensor and the advanced capacitive-type digital display dialimeter are used to accurately measure the small changes of the sample. The advanced PID algorithm and the all-optical isolation phase-modulation module are used for temperature control to ensure that the heating rate error is less than 0.5 °C.
Standard
ISO 2507 Thermoplastics pipes and fittings- Vicat softening temperature - Part1: General test method ISO 75 Plastics - Determination of temperature of deflection under load ISO 306 Plastics-Thermoplastic materials - Determination of Vicat Softening Temperature (VST) ASTMD 1525 Standard Test Method for Vicat Softening Temperature of Plastics ASTMD 648 Standard Test Method for Deflection Temperature of Plastics Under Flexural Load in The Edgewise Position
Technical Parameters
Model | HZ-1708 |
Temperature control range | Room temperature ~ 300 °C |
Maximum temperature error | ±0.5 °C (50 degree heating rate) ±1 °C (120 degree heating rate) |
Heating rate | 50℃/h,120℃/h |
Temperature measurement point | 1 |
Number of test racks | 4 pieces |
Deformation measurement range | -0.1~10mm |
Maximum deformation error | ±0.01mm |
Sample support span | 64mm,100mm |
Using media | Methyl silicone oil or transformer oil |
Cooling method | Natural cooling above 150°C, water cooling below 150°C or natural cooling |
The sample holder is automatically raised and lowered, and the thermal expansion coefficient of the sample holder is <0.005/100°C (directly affecting the experimental results) |