Product Details:
|
Model: | G50TH G71TH L125TH L150TH L150TH2 L200TH L225TH L250TH | Type: | PTC Electric Heater |
---|---|---|---|
Temperature Setting Range And Control Accuracy: | 18~25℃±1℃ | Humidity Setting Range And Control Accuracy: | 45~65%±5% |
Evaporator: | Copper Tube Finned | Power: | Three-phase380V/~/50Hz |
Refrigerant: | R410A | Control Accuracy: | ±5-10%. |
Number Of P: | 2 3 5 6 6 8 9 10 P | Items: | Cabinet Type (combined) Frequency Conversion Constant Temperature And Humidity |
Highlight: | 380V Wine Cellar Air Conditioners,R410A Refrigerant Three Phase Air Conditioner,PTC Three Phase Air Conditioner |
Wine Cellar Air Conditioner is used for indoor air conditioning under various environmental conditions, and has multiple functions such as cooling, dehumidification, heating, humidification, and ventilation. Temperature control range: when the temperature is set at 18-25°C, the control accuracy is ±0.5-1°C, the relative humidity is set at 50-70%, and the control accuracy is ±5-10%.
When the refrigeration system is working, the high-temperature and high-pressure R410 gas discharged from the compressor enters the condenser and is condensed into a medium-temperature supercooled liquid. After being throttled and depressurized by the expansion valve, it becomes a low-temperature and low-pressure gas-liquid two-phase mixture and enters the evaporator. It evaporates and absorbs the heat of the air passing through the evaporator, so that the air flowing through the evaporator can be cooled. After vaporization, the steam is sucked by the compressor, so that the cycle is continuous, so as to achieve the purpose of cooling.
Since the surface temperature of the fins of the evaporator is lower than the dew point temperature of the air, when the air flows through the surface of the evaporator, water will precipitate on the surface of the evaporator.
Heating: start the heater, when the air flows through the heater, the air is heated and the temperature rises.
Humidification: Start the humidifier, and the water vapor generated by the humidifier is continuously sent into the room by the fan to achieve the purpose of humidification..
The unit has a variety of models to choose from, and can be widely used in the air conditioning needs of electronic factories, hospitals, pharmaceutical factories, printing factories, post and telecommunications, banks, computer rooms, power supply and distribution stations, communication stations and other buildings.
items | Hanging constant temperature and humidity | cabinet type (combined) frequency conversion constant temperature and humidity | |||||||||||
Model | Indoor Unit | G50TH | G71TH | L125TH | L150TH | L150TH2 | L200TH | L225TH | L250TH | ||||
outdoor unit |
TK-WB
|
TK71WB | TK-125WB | TK-150WB | TK-150WB | TK200WB | TK225WB | TK250WB | |||||
number of p | P | 2 | 3 | 5 | 6 | 6 | 8 | 9 | 10 | ||||
Cooling capacity | kW | 5 | 7.1 | 12.5 | 15 | 15 | 20 | 22.5 | 25 | ||||
Electric heating | kW | 7.5 | 15 | 23.4 | 28 | 28 | 36 | 41 | 47 | ||||
indoor unit | air volume | m3 / h | 1150 | 1700 | 2500 | 3600 | 3500 | 5000 | 5000 | 5400 | |||
External residual pressure | Pa | 50/0 | 50/0 | 50/0 | 60/0 | 80/0 | 80/0 | 80/0 | 80/0 | ||||
noise | dB(A) | 52/54 | 54/56 | 58/60 | 58/60 | 58/60 | 62/64 | 62/64 | 62/64 | ||||
Temperature setting range and control accuracy | 18~25℃±1℃ | ||||||||||||
Humidity setting range and control accuracy | 45~65%±5% | ||||||||||||
power | 220V/~/50Hz | Three-phase380V/~/50Hz | |||||||||||
Refrigerant | R410A | ||||||||||||
Evaporator | Copper tube finned | ||||||||||||
throttling mode | Electronic expansion valve |