Product Details:
|
Noise: | 58~64dB(A) | Refrigerant: | R410A |
---|---|---|---|
Power: | Three-phase380V/~/50Hz | Model: | L125TH L150TH L150TH2 L200TH L225TH L250TH |
Humidity Setting Range And Control Accuracy: | 45~65%±5% | Temperature Setting Range And Control Accuracy: | 18~25℃±1℃ |
Items: | Cabinet Type (combined) Frequency Conversion Constant Temperature And Humidity | Type: | PTC Electric Heater |
Evaporator: | Copper Tube Finned | Number Of P: | 2 3 5 6 6 8 9 10 P |
Highlight: | R410A Refrigerant Wine Cellar Air Conditioner,Copper Tube Finned Evaporator Air Conditioner,65% Humidity Wine Cellar Air Conditioners |
Factory Air Conditioner is used for indoor air conditioning under various environmental conditions, and has multiple functions. Temperature control range: when the temperature is set at 18-25°C, the control accuracy is ±0.5-1°C, the relative humidity is set at 50-70%.
Factory Air Conditioner Dehumidification principle:
Humidification: Start the humidifier, and the water vapor generated by the humidifier is continuously sent into the room by the fan to achieve the purpose of humidification..
Technical Parameters
items | frequency conversion constant temperature and humidity | ||||||||
Model | Indoor Unit | L125TH | L150TH | L150TH2 | L200TH | L225TH | L250TH | ||
outdoor unit | TK-125WB | TK-150WB | TK-150WB | TK200WB | TK225WB | TK250WB | |||
indoor unit | air volume | m3 / h | 2500 | 3600 | 3500 | 5000 | 5000 | 5400 | |
External residual pressure | Pa | 50/0 | 60/0 | 80/0 | 80/0 | 80/0 | 80/0 | ||
noise | dB(A) | 58/60 | 58/60 | 58/60 | 62/64 | 62/64 | 62/64 | ||
Temperature setting range and control accuracy | 18~25℃±1℃ | ||||||||
Humidity setting range and control accuracy | 45~65%±5% | ||||||||
power | 220V/~/50Hz | Three-phase380V/~/50Hz | |||||||
Power | kW | 0.16 | 0.18 | 0.16 | 0.22 | 0.24 | 0.26 | ||
heater | Type | PTC electric heater | |||||||
Power | kW | 8 | 11 | 11 | 14 | 16 | 18 | ||
Humidifier | Type | PTC electric heater | |||||||
Maximum input power | kW | 8.5 | 11 |
Factory Air Conditioner Application
The unit has a variety of models to choose from, and can be widely used in the air conditioning needs of electronic factories, hospitals, pharmaceutical factories, printing factories, post and telecommunications, banks, computer rooms, power supply and distribution stations, communication stations and other buildings.
Factory Air Conditioner Cooling principle:
When the refrigeration system is working, the high-temperature and high-pressure R410 gas discharged from the compressor enters the condenser and is condensed into a medium-temperature supercooled liquid.